All data is for information only------(<---links)
PRODUCT DATA of IMI 115
MaterialIMI 115
Product DatasheetIMI115
Chemical CompositionCommercially Pure Titanium
Name of ManufacturerTIMET
The Hub,Holford Road, Witton, Birmingham B6 7AX, UK

+44 121 356-1155 EuroSales@timet.com
+44 121 356-5413
www.timet.com
EXPERIENCE IN PRACTICE
Development StatusCommercial Product
Cost RangeLow to Medium
Equivalent DesignationsTimetal 35A
Space ExperienceGood
PHYSICAL PROPERTIES
Specific Gravity4.51
Remark: @ Room Temperature
ELECTRICAL PROPERTIES
Electrical Volume Resistivity4.8e-7 ohm.m
Remark: @ Room Temperature
THERMAL PROPERTIES
Thermal Conductivity16 W/m.K
Remark: @ Room Temperature
Thermal Expansion Coefficient7.6 μstrain/°C
Remark: @ Room Temperature
RELEVANT PROPERTIES FOR USE IN SPACE COMMUNITY
Atmospheric CorrosionExceptional resistance to corrosion by oxidising media up to 700°C.
Bimetallic CorrosionCan be connected without any restriction to: Cr, Cu, Brass, Cu-Ni alloys, Al-bronzes, Si-bronzes, Gun metal, P-bronzes, Sn-bronzes, Ag, 300 and 400 series stainless steel, low alloy steel, Au, Pt, C, Rh
Can be connected in a non-controlled environment to the above and Ni, Monel, Inconel, Ni-Mo alloys
Can be connected in a clean room environment to above and Cd, Al-Cu alloys
Needs specific measures: All others
Test:ECSS-Q-ST-70C Rev.1 Table 5.1
Data Quality: Design Data
SPECIAL RECOMMENDATIONS
Special RecommendationsMethyl alcohol should not be used in the pressure testing of tanks since failure can occur due to stress-corrosion cracking. · Should have very low interstitial content (i.e. oxygen, hydrogen, nitrogen) to avoid hydrogen embrittlement, etc. This is particularly important when there is a need for welding or heat testing.
Lessons LearnedWelding procedures should always be checked. Argon or helium protection is essential on trailing direction and opposite side